Fluke Linkware 9.6版本免費(fèi)下載
Versiv (TFS) Release Notes for Version 4.7 Build 4 (June 2016)
You MUST install LinkWare 9.6 before updating your Versiv (TFS) to Version 4.7 Build 4.
This update covers the DSX‐5000 CableAnalyzer?, CertiFiber Pro?, OptiFiber Pro? modules and FI‐7000.
Instructions on how to update your units can be found here
1. New Features/Enhancements
Button on FiberInspector probe now active
? ?Press it once to automatically bring up the image of the connector end face
? ?Press it once more to freeze the image?SYNC button for LinkWare Live added to HOME screen
SYNC button for LinkWare Live added to HOME screen
? ?Once results are sent to LinkWare Live, you can import them into LinkWare PC
? ?In LinkWare PC, they appear the same as if you had connected via a USB cable?Manual Entry on launch compensation screen now has “(APC)” next to it
Manual Entry on launch compensation screen now has “(APC)” next to it
? ?If testing links with APC connectors, you should use Manual Entry for launch compensation
? ?When the first and/or last events have no measurable reflectance and the loss is below the event threshold?set, OptiFiber Pro will add a virtual event at those locations, ‐ but only if Manual Entry launch?compensation was used
2. Cable / Spec Database Change
Default OptiFiber Pro test limit now “General Fiber RL = 35 dB”
TIA‐568.3‐D updated
? ?Fiber loss @ 850 nm changed from 3.5 dB/km to 3.0 dB/km
? ?For OptiFiber Pro, three new limits added to help prevent links with poor reflectance passing:
1)?ANSI/TIA‐568.3‐D Link RL = 20 dB
2)ANSI/TIA‐568.3‐D Link RL = 35 dB
3) ANSI/TIA‐568.3‐D Link RL = 55 dB
?JIS X5150:2016 added, JIS X5150:2004 kept for legacy testing
For OptiFiber Pro, three new limits added to help prevent links with poor reflectance passing:
1)JIS X5150:2016 Fibre Link RL = 20 dB
2) ?JIS X5150:2016 Fibre Link RL = 35 dB
3) ?JIS X5150:2016 Fibre Link RL = 55 dB
?ABNT NBR 14565 (Brazilian) standards added for DSX CableAnalyzer
? ?Added Automotive limits under a new folder ‐ Transportation
? ?OptiFiber Pro “General Fiber” limits renamed/corrected, values do not change: